Mfg Part Number: 103Y773P021 | NSN : 5945-00-984-4482 | NIIN : 009844482 |
CAGE Code : 03538 | Manufacturer: Other | Item Name : Relay Electromagnetic |
FSC : 5945 Relays and Solenoids |
Thank you for your continued interest in 103Y773P021 under NSN 5945-00-984-4482 components available for purchase on Integrated Plane Parts. The Relay Electromagnetic item associated with the part number 103Y773P021, manufactured by Other, is currently available on our database; as such, we ask that you please fill out and submit an Instant RFQ form detailing your requirements on parts needed. Details should include desired quantities, target prices, expected shipping time frames, and more, as applicable. Upon receipt of a completed form of 103Y773P021, our representatives will harness your provided information and formulate a solution which satisfies your operational needs in just 15 minutes or less.
With our global supply chain stretching across the United States, Canada, and the United Kingdom, Integrated Plane Parts can provide expedited shipping on select orders for entities facing an Aircraft on Ground (AOG) situation or a variety of additional unique time constraints.
Operating with a strict NO CHINA SOURCING pledge, all orders are shipped alongside their manufacturer trace documentation or qualifying certifications, ensuring that customers can feel confident in every purchase made. With cost savings and rapid lead times bolstering every order, experience all we have to offer by submitting your RFQ for NSN 5945-00-984-4482 items under FSC 5945 Relays and Solenoids with the CAGE Code 03538 by Other, today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-984-4482 Item Description: Relay Electromagnetic | 5945 | 009844482 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
103y773p021 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.420 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 5.0 AMPERES AC SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.620 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.120 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.136 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.3 KILOHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
![]() |